Did you know there are many options to consider when selecting thermal fluids?

  1. Temperature is Everything – match your bulk temperature but also consider film temperature, heater type
  2. Controlling Oxidation – high temperature air exposure can destroy the wrong fluid quickly
  3. Maximizing Fluid Life – short-term or long-term use – invest wisely
  4. Availability is Critical – thermal fluids are often critical to production – how long can you wait for your thermal fluid to ship?
  5. Reliable Service & Support – thermal fluids are maintenance-intensive, but can your vendor help you if there are problem

Read More

PRODUCTS

Duratherm 600

Rated to 316°C (600°F) and specifically engineered to withstand the extreme oxidation environment of open (to atmosphere) systems, the Duratherm 600 thermal fluid incorporates a proprietary dual-stage anti-oxidant for long, trouble free operation in a variety of applications. It’s an environmentally friendly, non-toxic thermal fluid (heat transfer fluid) capable of providing precise temperature control.

  • 316°C (600°F) maximum operating temperature
  • A tough thermal fluid made for a variety of applications
  • Engineered for use in heat transfer applications with exposure to air
  • Superior protection against sludge and carbon formation
Standard
Metric

Temperature Ratings

Max Bulk/Use Temp 316°C
Max Film Temp. 343°C
Pour Point ASTM D97 -10°C

Safety Data

Flash Point ASTM D92 224°C
Fire Point ASTM D92 240°C
Autoignition ASTM E-659-78 360°C

Thermal Properties

Thermal Expansion Coefficient 0.1011 %/°C
Thermal Conductivity W/m·K
38°C 0.138
100°C 0.136
204°C 0.130
204°C 0.130
260°C 0.128
288°C 0.126
316°C 0.125
Heat Capacity kJ/kg·K
38°C 1.930
100°C 2.130
204°C 2.460
204°C 2.462
260°C 2.642
288°C 2.730
316°C 2.818

Physical Properties

Viscosity ASTM D445 cSt
40°C 40.26
100°C 6.48
204°C 1.54
204°C 1.53
260°C 1.01
288°C 0.86
316°C 0.75
Density ASTM D1298 kg/l
38°C 0.83
100°C 0.79
204°C 0.72
204°C 0.72
260°C 0.68
288°C 0.66
316°C 0.65
Vapor Pressure ASTM D2879 kPa
38°C 0.00
100°C 0.00
204°C 0.40
204°C 0.41
260°C 2.34
288°C 4.96
316°C 9.86
Distillation Range ASTM D2887
10% 374°C
90% 481°C
Molecular Weight 372
Specific Gravity @ 16°C 0.868

Note: The values quoted in the table above are typical of normal production.
They do not constitute a specification.

Temperature Ratings

Max Bulk/Use Temp 600°F
Max Film Temp. 650°F
Pour Point ASTM D445 14°F

Safety Data

Flash Point ASTM D92 435°F
Fire Point ASTM D92 464°F
Autoignition ASTM E-659-78 680°F

Thermal Properties

Thermal Expansion Coefficient 0.0564 %/°F
Thermal Conductivity BTU/hr·ft·F°
100°F 0.080
212°F 0.079
399°F 0.075
500°F 0.074
550°F 0.073
Heat Capacity BTU/lb·F°
100°F 0.461
212°F 0.509
399°F 0.588
500°F 0.631
550°F 0.652

Physical Properties

Viscosity ASTM D445 cSt
40°F 304.53
100°F 44.33
260°F 3.94
Density ASTM D1298 lb/ft³
100°F 51.69
212°F 49.13
399°F 44.85
500°F 42.54
550°F 41.39
Vapor Pressure ASTM D2879 psia
100°F 0.00
212°F 0.00
399°F 0.06
500°F 0.34
550°F 0.72
Distillation Range ASTM D2887
10% 705°F
90% 898°F
Molecular Weight 372
Specific Gravity @ 60°F 0.868

Note: The values quoted in the table above are typical of normal production.
They do not constitute a specification.